Flow Controller Kofloc


 High Grade Metal Flow Controllers
MODEL 5100 SERIES
 Model 5100 Series Mass Flow Controller/Meter features weldless structure, metal seals, accurac y of ≤±1%, re-sponse of ≤±1 second and other basic performance con-ditions required for semiconductor process control, and additionally, has achieved a significant price reduction.

Features

-High accuracy and high response are achieved by the flow sen-sor with temperature-  following current difference detection.

-A normally-closed solenoid valve is employed.
-A low leak rate is achieved by the weldless structure and metalseal.
-The dead volume is reduced thanks to the diaphragm seat valve.
-The face-to-face and body dimensions and the wiring tie-inpoints are designed to  facilitate replacement of devices made by other companies. 
Standard Spesifications
Flow range (N2 equivalent,
20
/1 atm)
1 SCCM–20 SLM (The conditions are freely selectable)
Sensor
Thermal mass flow sensor
Valve type
Proportional solenoid valve (closed when not energized)
Control range
2–100% (F.S.)
Response
1 sec. or less (0–100% within ±2% typical)
Accuracy
±1% F.S. (Accuracy guaranteed at 15–35)
Repeatability
±0.2%F.S.
Operating differential
pressure
F.S. ≤ 5 SLM: 50–300 kPa
F.S. > 5 SLM: 100–300 kPa
Option: Low differential pressure (LP) specification is available depending on conditions.
Allowable operating pressure
300 kPa (G) or less
Proof pressure
980 kPa (G)
Leak rate
1 × 10-11 Pa·m3/s  or less
Allowable ambient temperature
0–50
Allowable ambient humidity
10–90% (No condensation allowed)
Materials of parts in
contact with gases
Body: SUS316L
Diaphragm:SUS316L
Valve seat: PTFE
Sealing: SUS316L, Ni, Au
Option: SUS seal (SU), inner surface polish (KP)
Electric connection
Dsub 9-pin connector as per KFC Standard (Compliant with SEMI Standard)
Flow rate input signals
0–5 VDC (Input impedance: 1 MΩ or more)
Flow rate output signals
0–5 VDC (External load resistance: 250 kΩ or more)
Required power supply
+15 VDC (±5%) 100 mA, −15 VDC (±5%) 200 mA
Joint (Main unit bore)
Standard: 1/4 VCR equivalent Option: 1/4 SWL
Weight
Approx. 1000 g

Harness Layout
 Pin Assigment of Dsub 9-pin Connector per KFC Standard
Pin No
Signal
Pin No.
Signal
1
Input valve open/close operation
6
Flow input Hi
2
Flow output 0-5 V
7
Flow output COM
3
+15 VDC power source
8
Flow input Lo
4
Power source COM
9
Output valve voltage
5
-15 VDC power source


Because a differential input system in used for the product, pin 4 (power source COM) and pin 7 (flow outpum COM) are connected inside the mass flow controller while pin 8 (flow input Lo) is isolated. In case of a single-ended connection , connect pin 8 to pin 4