Sabtu, 01 Desember 2012

Irrigation Magmeter ; Electromagnetic Flow Meter



The AG2000 is a spool-type electromagnetic flowmeter for use in irrigation applications in 4” to 10” pipe. With no moving parts, these meters have unobstructed flow and are resistant to wear from debris found in ground or surface water. There are no bearings or propeller to wear out. Minimal straight pipe requirements allow AG2000 flow meters to be used in piping configurations where there is little space between the flow meters and an elbow.

In chemigation applications, the flow meter should be installed upstream of the chemical injection point or enough downstream to allow thorough mixing of fluids ahead of the meter (see Tech Bulletin on Seametrics website Downloads page).

The standard electromagnetic flow meter AG2000 is battery powered.  Where an external power source is available, the Magmeter AG2000 can be optionally converted to 7-26 Vdc, with the batteries then serving to maintain continuous operation in case of power failure. This configuration will prolong battery life indefinitely.

The Electromagnetic flow meter comes with built-in pulse output (requires optional output cabling) for data logging or telemetry. Several pulse rates are available. An internal data logger is also available for secure flow logging (-127).  A Seametrics FT420W indicator can be added if remote rate/total reading is desired, or an AO55W if a 4-20 mA (analog) signal is required.


The Magmeter AG2000 has a seal wire to protect against unauthorized access. The seal can be broken to change units of measure, replace the battery pack, or to field-install a power/output cable. The optional cable can be factory- or field-installed for applications where external power is available and/or pulse output is needed. The accessory weather guard is recommended in outdoor applications.

FEATURES
• Simple as a mechanical meter
• No moving parts
• Minimal straight pipe required
• Battery power standard;   External power optional
• Solar compatible
• Built-in rate & total indicator
• Built-in pulse output for data-   logging or telemetry
• Tamper-evident seal


APPLICATIONS
• Irrigation
• Chemigation
• Agricultural automation
• Well usage monitoring
• Dairy Lagoons


Jumat, 30 November 2012

Low Flow Magmeter



The PE102 magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in 3/4” to 1/4” pipe/tube. The housing is made of sturdy splashproof HDPE plastic.

With no moving parts, the PE102 can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 microSiemens) of varying viscosities and densities.

FEATURES
• No moving parts
• Requires no straight pipe
• Pulse and/or 4-20 mA output
• Chemical and corrosion resistant
• Insensitive to fluid density and fluid viscosity changes

APPLICATIONS
• Chemical injection
• Corrosive materials
• Low flow applications
• Pulsating flows (e.g., metering pump)

The PE meter is compact enough to fit most pump/injection systems. With zero straight pipe required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability. 

The PE meter has optocoupled current sinking or current sourcing pulse output that can be connected to the Seametrics FT420 rate/total display or FT520 batch processor, as well as a 4-20 mA loop for powering analog devices. Outputs and power are provided through a cable with 8-pin female circular connector.


Insertion Flow Meter



Insert Flow Meter

EX80-SeriesDownloads
Magnetic MeterFixed Depth Insertion Magmeter
• Low-flow performance and accuracy superior to any mechanical flow sensor
• No moving parts to wear out
• Dedicated fittings for simple installation
• Retainer clip automatically sets correct depth
• Meter extends only ~1/8 of pipe diameter, minimizing potential for clogging with debris
• Simple pulse train output can be used with any SeaMetrics signal processing module, or sent directly to a PLC
• Available for pipe sizes 1" to 10", in Brass, 316 Stainless, PVC, and CPVC

EX100/200Downloads
EX100/200The complete lack of moving parts of the EX100/200-Series insertion flow sensor is the source of its reliability. Brass and stainless steel models withstand a variety of temperature, pressure, and chemical conditions. The EX-Series has no rotor to stop turning in dirty water and there are no bearings to wear out.

IP80Downloads
IP80The IP80-Series are impeller (or “paddlewheel”) insertion meters designed for use with a wide variety of liquids in pipe sizes 1/2" to 8". Sensors are available in brass, 316 stainless
steel, PVC, and polypropylene. Bodies are machined from a solid rod for maximum precision. High-quality jewel bearings and nickel-bound tungsten carbide shafts are used for extreme low friction and long life.

IP100/200Downloads
IP101/102The IP100/200-Series are adjustable depth insertion paddlewheels that come in brass or 316 stainless models
to fit 3” to 48” pipe. Installation fittings are standard 1-1/2" (101/201) or 2” (115/215) NPT. Fittings such as saddles and weldolets may be purchased either locally or from SeaMetrics.

TX80Downloads
TX80The TX80-Series are insertion turbine meters designed for use in 1-1/2" to 8" pipe. High-quality jewel bearings and precision shafts ensure long life and low friction. Available
in 316 stainless steel, brass, PVC and polyprolylene, sensor bodies are machined from solid rod for maximum low-flow performance. The TX80-Series use special fittings that ensure ease of installation and correct depth setting in the pipe.

TX100/200Downloads
TX100/200The TX100/200-Series are adjustable depth insertion turbines
that come in brass or 316 stainless models to fit 3” to 48” pipe. Installation fittings are standard 1-1/2" (101/201) or 2” (115/215) FNPT. Fittings such as saddles and weldolets
may be purchased either locally or from SeaMetrics.

Fittings for 80 SeriesDownloads
Series 80 FittingsSeaMetrics insertion meters must be seated in fittings that match
the pipe size and material.