Flow Controller Kofloc


 High Grade Metal Flow Controllers
MODEL 5100 SERIES
 Model 5100 Series Mass Flow Controller/Meter features weldless structure, metal seals, accurac y of ≤±1%, re-sponse of ≤±1 second and other basic performance con-ditions required for semiconductor process control, and additionally, has achieved a significant price reduction.

Features

-High accuracy and high response are achieved by the flow sen-sor with temperature-  following current difference detection.

-A normally-closed solenoid valve is employed.
-A low leak rate is achieved by the weldless structure and metalseal.
-The dead volume is reduced thanks to the diaphragm seat valve.
-The face-to-face and body dimensions and the wiring tie-inpoints are designed to  facilitate replacement of devices made by other companies. 
Standard Spesifications
Flow range (N2 equivalent,
20
/1 atm)
1 SCCM–20 SLM (The conditions are freely selectable)
Sensor
Thermal mass flow sensor
Valve type
Proportional solenoid valve (closed when not energized)
Control range
2–100% (F.S.)
Response
1 sec. or less (0–100% within ±2% typical)
Accuracy
±1% F.S. (Accuracy guaranteed at 15–35)
Repeatability
±0.2%F.S.
Operating differential
pressure
F.S. ≤ 5 SLM: 50–300 kPa
F.S. > 5 SLM: 100–300 kPa
Option: Low differential pressure (LP) specification is available depending on conditions.
Allowable operating pressure
300 kPa (G) or less
Proof pressure
980 kPa (G)
Leak rate
1 × 10-11 Pa·m3/s  or less
Allowable ambient temperature
0–50
Allowable ambient humidity
10–90% (No condensation allowed)
Materials of parts in
contact with gases
Body: SUS316L
Diaphragm:SUS316L
Valve seat: PTFE
Sealing: SUS316L, Ni, Au
Option: SUS seal (SU), inner surface polish (KP)
Electric connection
Dsub 9-pin connector as per KFC Standard (Compliant with SEMI Standard)
Flow rate input signals
0–5 VDC (Input impedance: 1 MΩ or more)
Flow rate output signals
0–5 VDC (External load resistance: 250 kΩ or more)
Required power supply
+15 VDC (±5%) 100 mA, −15 VDC (±5%) 200 mA
Joint (Main unit bore)
Standard: 1/4 VCR equivalent Option: 1/4 SWL
Weight
Approx. 1000 g

Harness Layout
 Pin Assigment of Dsub 9-pin Connector per KFC Standard
Pin No
Signal
Pin No.
Signal
1
Input valve open/close operation
6
Flow input Hi
2
Flow output 0-5 V
7
Flow output COM
3
+15 VDC power source
8
Flow input Lo
4
Power source COM
9
Output valve voltage
5
-15 VDC power source


Because a differential input system in used for the product, pin 4 (power source COM) and pin 7 (flow outpum COM) are connected inside the mass flow controller while pin 8 (flow input Lo) is isolated. In case of a single-ended connection , connect pin 8 to pin 4


Flowmeter Kofloc


Compact Readout Unit
MODEL CR-400
The CR-400 readout unit, when connected to your mass flow control-ler or meter with a cable, provides the key mass flow functions, such as flow measurement and control as well as cumulative flow calcula-tions and flow event outputs. This readout unit offers RS-485 commu-nications capability, so multiple readout units can be controlled online by a host computer. * The CR-400 is fully compatible in size with the CR-300.
Features
  1. Total flow is displayed in 8 digits : The upper 4 digits and the lower 4 digits are shown alternately.
  2. Various event outputs are available.
  3. With a width of 73mm and height of 73mm, it takes up little space.
  4. Equipped with forced open/close operation of mass flow controller valve.
  5. External control terminals are provided on the rear for remote control
  6. Mass flow control by RS-485 communications
  7. A lock key prevents  accidental operation.
  8. Mass flow power : ±15 VDC (300 mA)
  9. Mass flow power: ±15 VDC (300 mA) 

Standard Spesifications
Mass flow control
Flow setting, forced valve open/close operation and zero cut
Mass flow input/output
05 VDC
Number of display digits

Instantaneous flow: 4 digits, total flow: 8 digits (upper and lower 4 digits
shown alternately)
Display accuracy
Instantaneous flow: Within ±0.1% F.S. ±1 digit
Event output

2 outputs (selected from instantaneous upper limit, instantaneous lower limit,
instantaneous upper/lower limits, and set total)
Open collector output (max. rating: 50 V, 50 mA)
Power consumption
Approx. 25 W
AC power supply
85264 VAC, 48440 Hz
Weight and dimensions
Approx. 400 g, 73 W × 73 H × 119.5 D mm


Selasa, 30 Agustus 2016


Coriolis Mass Flowmeter AMF008(TL4I)
Coriolis mass flowmeter is developed according to the principle of coriolis mass flowmeter, it can be directly measure parameters such as mass flow , density and temperature. It has been widely used in petroleum, natural gas, chemical, pipeline transportation industries. Its function is for trade settlement and process control to ensure precision reflection, enhanced safety and maintenance cost save.

Product Information
AMF series Coriolis meter's mass flow can yield up to 0.15% accuracy. It is incredibly accurate and excellent repetition. And allows you as producer to make consistency and repeatability of batches.
Direct mass flow. Do not lose the accuracy by measurement of T, P, Z &ρand Volume conversion.
It can measure more than one variate in the tube. Such as mass flow, volume flow, density, concentration, temperature and viscosity.
It's lower maintenance. There is no moving parts in Coriolis meter and no impellers and obstructions in the line. So, There is no movement and wearing mar. The meter's last forever.
Measure high viscosity and non- Newtonian fluid, besides homogeneous fluid, not only single phase fluid can be measured, but also homogeneous multi- phase fluid.
Good antiseptic property, various common corrosion fluids can be measured.

Specifications
Independent Parameter

Model
DN mm
Max. Flow-rate kg/min
Characteristic
Mounting Type
Conn. Size(Customizable)
W.P MPa
Code for Product
Certifications of Explosion-proof and Protection
AMF008
8
50
Cryogenic
Integrated
Flange HG/T20592 DN15 PN40 (RF)
≤4
AMF008-TL4I
IP67
CNEX
Ex d ib C T6 Gb

Accuracy
Grade 0.15, Grade0.2, Grade0.5, Grade1.0……
Density
±0.001g/cm3
Ambient temp
-25+55
Relative humidity
≤95%
Measuring medium
Gas,Liquid
Medium temp
Cryogenic: -196+70;
Normal temp.: -40
+70
Meter tube mat’l
316L
Output
Modbus/RS-485:
The default baud rate is 38400bit/s. Refer to table 3 for details.
Pulse output signal: 
Passive: Open collector, max 36VDC,100mA,electric isolation.
Pulse output: The value is optional. Pulse polarity is positive.
 
Refer to table 5 for details.
Current output(only for with display):
Passive: 4
20mA HART. Power: 12VDC40VDC
RL<700Ω, Resolution ratio: 2.24uA
Power voltage
12VAC30VAC / 15VDC40VDC
Elect. Conn
M20×1.5


Standard parameter of communication of Modbus/RS-485
Protocol
Modbus Protocol
Device Type
Slave for the device
The range of address
1…247
Broadcast address
170
Function code
03Read holding register
04
Read input register
06
Read-in single register
16
Read-in multiple register
Support baud rate
1200, 2400, 3600, 4800, 9600, 19200 , 38400 (default) , 57600 , 115200 ( BAUD)
Data transfer mode
RTU
Data access
Access device parameter through Modbus/RS-485 (Refer to Appendix C for information of Modbus register)

Installation

Installation Instruction
a. The flowmeter shall be installed firmly and mounted on the support frame, and no obvious vibration source is allowed in the installation area. The ambient temperature shall be in the range of -25℃ to +55℃, and effective measures shall be taken for rain-proof and water-proof. 
b. In case the measured medium is gas, please refer to article “installation type” for recommended installation type.
3.In case the measured medium is liquid, please refer to “installation type” for recommended installation type.
c. The wiring terminal of the transmitter is in the wiring chamber of the transmitter, the wiring terminal can be seeing when the wiring cover of the transmitter is open.
Installation Methods
a. When measure gas: horizontal upwards or vertical, horizontal upwards refers to the meter tube (inside the housing) should be located upward, and upside-down is forbidden. 
b. When measure liquid: horizontal downwards or vertical, horizontal downwards refers to the meter tube (inside the housing) should be located downward, and upside-down is forbidden.