AMC3100series Converter With temperature/ energy function can be used with AMF series flowmeter in both compact or separate versions .
FEATURES :
Four line LCD display Flowrate/ Energy/ Totalizer
Accuracy of + / -0.4% of reading
Bi-directional flow measurement, current and pulse output
Large digital display, With temperature / energy function
99 times records for power on/ off
MODBUS / HART communication
SPECIFICATION:
Excitation : Square wave
Display : 4 lines LCD with back light
Line 1 : Date and Time
Line 2 : 6 digit flowrate, 7 digit energy value
Fault code : Supply temperature
Line 3 : 9 digit totalizer for forward / reverse flow
9 digit totalizer for heat / cold energy
Fault code content
Return temperature
Line 4
Differential temperature
Unit : L/ S , L/ M , L/ H , M3/ S , M3/ L , M3/ H KW , MW , KJ/ H , MJ/ H , GJ/ H
Measuring Range: Min. 0 to 0.15 m/ s
Max. 0 to 15 m/ s
Accuracy: + / -0.4% of reading ( Velocity > = 0.5 m/ s)
+ / -0.002 m/ s ( Velocity < 0.5 m/ s)
Repeatability: + / -0.1% of reading
Current Output: 4-20 mA ( Isolated)
Load : Max. 600
Pulse output : Open collector
Rating
3 to 30 VDC, 20 mA Max.
Pulse Rate : 1) Scale pulse, ( Pusle/ M3, Pulse/ L, Other)
2) Frequency, 0-5000 Hz
Communication : RS 485( MODBUS Protocol)
HART signal
Data Storage : Operation parameters and totalization
figures are stored by EEPROM for more
than 10 years
Self Diagnosis: The following errors during application
can be indicated
- Coil failure
- Power failure
- Overlarge output
- Internal error
- Overlarge flow
- Empty pipe
Cable Entry: PG11
Protection Class: IP 67 , IP 68( Submersible)
Explosion Proof, Exd( ib) ibqIIBT5
Ambient Temp.: -25 ~ + 65oC
Housing Material: Aluminum alloy
Power Supply: 3.6V battery supply
Battery Life: 2~ 3 years
Determined by size & function
Communication Protocol: RS 485( MODBUS protocol)
Weight: 2.0 Kg ( Compact) , 4.3 Kg ( Separate)
Mounting: Wall mounting
Bracket on 2 " pipe
Compact version( Install on sensor)
Keyboard : 4 keys from external for programming and display control.
Low Flow Cutoff : 0 to 9.9 %
Datalogger Function : 99 times records for power on/ off
Record Data : Date/ Time when Power on/ off, 99 years flow rate / energy /
Temperature / Total flow / Total energy
One Record Data per Hour
Damping : 0.1 to 99.9 Second
Self Diagnosis : The following error message is indicated during application
- Coil fail
- Power fail
- Output overanged
- Internal error
- Overflow
- Empty pipe
Cable Entry : PG11
Protection Class: IP 65
Ambient Temperature: -25 to + 65 oC
Material : Aluminum Alloy
Temperature Input: PT1000, 2 wire
Power Supply: 90-260 VAC, 50/ 60 Hz
24 VDC + / - 10% ( Option)
Power Consumption : 3-17 W ( depending on the sensor size)
Weight : 1.4 Kg
Mounting: Wall mounting
Bracket on 2 " pipe