Alia Flow Meter
Alia Tube Flow Meter
|
|
|
| AVF250 Series |
|
ALIAVA AVF250 Series is a flowmeter commonly used in Auto-industry process control. It's with small volume, wide range and easily operation. It could also measure liquid, gas and steam flowrate, especially fit for small flowrate application. |
|
|
|
| FEATURES |
|
4 digit flowrate & 8 digit totalizer
Local indication without auxiliary power
4-20 mA & Scale pulse output
Low pressure lost on gas and steam application
Damper for Gas/Steam application
Consistent overall length
Heating jacket design
Intrinsically safe & explosion proof for hazardous area |
|
| SPECIFICATION |
|
| Size: | Local Display: |
| 15,20,25,40,50,65,80,100,125,150,200 mm | Mechanical Indicator (standard) |
| Measuring Range: | Digit Display |
| Liquid - 1 ~ 200000 Liter/Hr | 4 Digit Flowrate |
| Gas - 0.03 ~ 4000 M3/Hr | 8 Digit Totalizer |
| Turndown Ratio: | Current output: |
| 10:1 (20:1 Optional) | 4-20 mA(2 Wire) |
| Accuracy: | Load |
| +/-1.6%(Standard) | Max. 600 |
| +/-1.0%(Optional) | Pulse output: |
| Repeatability: | Open collector (Scale pulse) |
| +/-0.5% value of reading | Rating |
| Material: | 3 to 30Vdc, 100 mA Max. |
| Tube & Float | Data Storage: |
| Stainless Steel 304 | Operation parameters and totalization |
| Stainless Steel 316 | figures are stored by EEPROM for more |
| Stainless Steel 316L | than 10 years |
| Stainless Steel + PTFE Liner | Alarm output: |
| Standard Pressure: | 2 point (open collector) |
| 40 Kg/cm2 (15mm ~ 50mm) | Rating |
| 16 Kg/cm2 (65mm ~ 200mm) | 3 to 30Vdc, 100 mA Max. |
| Temperature: | Keyboard: |
| 3 keys from internal for programming |
| -25 ~ +100oC (LCD Display) |
| and display control. |
|
| Ambient temperature: |
|
|
|
| Flange Type: | Protection class: |
| JIS 10K / JIS 20K / JIS 40K | IP 65 |
| ANSI 150# / ANSI 300# / ANSI 600# | Intrinsically Safe, Eex ia IIC T5 |
| DIN PN 10 / PN 16 / PN25 / PN 40 | Explosion Proof, Ex d IIB T6 |
| Fluid Viscosity: | Housing Material: |
| 300 CP Max. | Aluminum Alloy |
| Communication: | Cable entry: |
| RS485(MODBUS Protocol) | M20 * 1.5 |
| HART Signal | Pressure Drop: |
| 0.07 ~ 0.7 Kg/cm2 |
| Power supply: |
| 11 ~ 36VDC( 2 wire 4-20 mA) |
| Ni-MH Battery(3 years working hours) |
|
|